Kimmco duct insulation kdip pdf

Nominal thickness, 25100 mm water vapor permeance is 0 perms meeting the requirements of table 1 of bs 5422. Kimmco isover stone mineral wool products combine high thermal insulation performance with noise control and fire safety. Kimmco building slab kbs standard dimensions for thermal and acoustic insulation of concrete floors in order to reduce energy losses and transmission of impact sound. This way, youre not turning the wrap off, just freezing and you can thaw it after the hangers have been placed. Solutions for hvac ducts and pipes, offering the best combination of thermal and acoustic comfort, energy efficiency and safety. The top countries of suppliers are china, taiwan, china, and malaysia, from which the percentage of duct rubber insulation supply is 99%, 1%, and 1% respectively. With forcedair systems, the ducts that carry the heated or cooled air throughout the home are often located in attics or other unconditioned spaces where temperatures are quite different from that of the air in the ducts. Low density fiber glass insulationinsulation board faced products msds no. For insulating mechanical systems, fiberglass pipe insulation offers cost effective solutions for a wide range of uses.

Hvac ducting details cad files, dwg files, plans and details. Kingspan therma tm duct insulation can withstand the loads imposed by hvac building services ductwork at locations where ductwork supports and hangers are installed. Kingspan insulation hasnt formatted technical specifications for koolduct system yet. For thermal and acoustic insulation external of hvac equipment and air distribution duct systems.

Duct insulation products construction materials sweets. This product is designed to meet existing performance standards such as nfpa 90a and 90b and other mechanical and energy codes. It is available in wall thicknesses of 38, 12, 34 and 1, in sizes ranging from 38 cts to 4 ips. The selected ductliner must be dry and free from offcuts, dust, grease, solvents, etc. Touch n seal products are ideal for air sealing and insulating homes and buildings.

Aeromat duct liner shall also be secured with mechanical fasteners, either impactdriven or weldsecured, which shall compress the duct liner. The ductwork in your commercial facility, like the ductwork in your home, is the critical channel that carries heated and cooled air from your hvac system to your offices, warehouses and work areas. Armatuff plus ii is designed for installation in above ground applications. Primary combustion products are nitrogen oxide, carbon monoxide, carbon dioxide, ammonia, hydrogen chloride and water. Background introduction of forced air heating, ventilating, and air conditioning systems established the need for duct insulation. In addition to the panel, offers a complete set of tools and accessories that allow ductwork to satisfy any project and installation requirement as well as thermal insulation panels for roof insulation, wall insulation, floor insulation and false ceiling with different sorts of facing like kraft paper. Insulation edi duct insulation with aluminum foil facing single sided kvalue. It has become a leading insulation solution provider in the middle east, africa, and asia. Hvac ducts handbook sustainable insulation solutions.

Our insulation products for south africa include thermal and acoustic materials whether you are looking for duct insulation, pipe insulation. Tssc preinsulated ductwork system is used as an alternative for operation such as fresh air, supply, return and exhaust air ductwork for hvac system. This certificate is an electronic document, subject to the terms and conditions of the product certification system and shall not be reproduced except in full. Energy efficiency and environmental protection with kimmco glass mineral wool more and more specifiers and users are insisting on the use of insulation materials that not only deliver technical performance but also offer. Your new online msds binder is a place for you to store the material safety data sheets you need to deploy. A uniquely tough skin surface is easy to clean and functional, providing an ideal surface to resist moisture and dirt. Duct insulation plus kdip duct insulation with aluglass facing single sided kvalue. Kingspan therma tm duct insulation can be fabricated on site to form two different types of insulated duct support inserts. This drawing also includes typical hvac ducting details such as traverse join, tappers off sets details, parallel flow branch, splitter damper, elbow construction, radius elbow turning vane, duct insulation, flexible duct connection, duct hangers and support, duct riser supports from floor with typical duct connection cross joint details. Fibrous glass duct liner standard insulation institute. Duct liner board is intended for use in commercial, institutional, industrial and residential construction as thermal and acoustical insulation of heating airconditioning and interior of dualtemperature duct work, air handling equipment and plenums operating at airvelocities up to. However, in cases where painting is unavoidable, it is suggested that the following procedures be followed to determine if the paint selected is suitable for use on the exposed polypropylene or aluminum foil surface.

Bonding multiple layers of fibrous insulation board. For insulation of single leaf walls with dressed stone or marble facings, curtain wall and cavity wall construction, precast structures and prefabricated buildings. Fsk, aluglass, black glass fabric application fields. Kimmco self seal is a selfadhering glasswool board for thermal and acoustic insulation of hvac ducts and similar applications, which completely eliminates the use of liquid and flammable glue, improves greatly the ease and speed of installation and saves installation cost and time. Kimmco lamella insul is suitable for wide range of applications in hvac and industrial sector such as. Duct wrap frk product data sheet industrial insulation.

Stability and reactivity chemical stability stable conditions to avoid none expected incompatible materials none expected hazardous decomposition products see section 5 for hazardous decomposition products during a fire possibility of hazardous reactions hazardous polymerisation. Insulation duct accessories the home depot store finder. Duct insulation comes with code requirements for maximum. Duct wrap frk product data sheet description softr duct wrap is a blanket of glass fi ber insulation factorylaminated to frk vapor retarder facing. Duct insulation with aluglass facing single sided kvalue. Kimmco duct insul kdi external insulation of rectangular and circular air ducting kiaamco duct insul kdi is in the form of flexible rolls, semirigid and rigid slabs manufactured from stable glass fibers bonded with thermosetting resins, and free from coarse fibers and shot. Duct insulation plus kdip is manufactured from stable glass fibres bonded with thermosetting resins, in the form of blankets, semirigid or rigid boards with factory applied aluglass aluminium foilglass fabric laminate facing as vapour barrier. Apply adhesive to both the rough side of the insulation 100% coverage and the duct 100% coverage. Surface burning characteristic as per astm e 84 satisfies the maximum requirement for flame spread index 25 and smoke developed index 50. Industrial insulation, pipe insulation, blanket insulation, board insulation, duct insulation, fyrewrap, insulation jacketing, fitting covers, insulation mastic, caulk, firestop, spray foam. A 2 50mm stapling and taping fl ange is provided on one edge. On large pipes, pipe cluster, or over heating traces, where performed insulation is not appropriate. Kimmco self seal is a selfadhering glasswool board for thermal and acoustic insulation of hvac ducts and similar applications, which completely eliminates the use of liquid and flammable glue, improves greatly the ease and speed of. Semirigid and rigid slabs manufactured from stable glass fibres bonded with thermosetting resins, and.

Click here to find out more about our latest products climaver, ecobuild and selfseal roll. However, you can download 3 technical files, 1 specifications file in the section below. Products containing vinyl films should not be painted as there may be longterm compatibility issues between the paint and the oils in. Pipes boilers equipment ducts fire stopping fabrications. The attached scope of certification bearing the same certificate no.

Sustainable and efficient solutions for building insulation. Kimmcoisover products are available as boards, blankets or lamellas for the insulation of rectangular ductworks. Knolco building roll vor kth,mco building slab vos kimmco duct insul kdi kimmco duct plus kdip kmmco duct liner kdl kimmco glass duct kgd kimmco rigid pipe covering k450, k850 kimmco acoustic panel kimmco clean liner kcl kkl 36 kimmco kalining. The doublesided skin can be used with either side facing away from the applied surface, resulting in less waste if one side. As a onestop insulation solutions shop in johannesburg, insulpro cc offers insulation solutions across all temperature ranges and applications. Kimmco glasswool rockwool free download as pdf file. In fitting ductliner insulation, ensure that all junctions are tightly butted together to prevent heat leakage. A wide variety of duct rubber insulation options are available to you, there are 514 suppliers who sells duct rubber insulation on, mainly located in asia. Jul 12, 2015 register now and get a free online msds binder. Duct insul plus kdip applications thermal and acoustic insulation external of hvac equipment and air distribution duct systems. Insulation can also be installed on the inner wall of the duct duct liners, as glass wool duct wraps or duct slabs faced with a glass matting or mesh providing acoustic insulation and strengthening the inner face of the duct. Kimmco lamella insul is designed for thermal insulation of pipes, ducts and vessels. Kimmco isover products are available as boards, blankets or lamellas for the insulation of rectangular ductworks. Section 230553 identification for hvac piping and equipment.

Kimmcoisover manufactures glass mineral wool insulation solutions for hvac and other applications in its plant located in kuwait. Product identification acoustiglass tm alleyk pipe insulation tm tc liner tm ak board tm alleywrap tm tc liner r tm fsk duct wrap tm alley wrap fsk tm umbi unfaced metal building insulation tm akoustiliner tm ap insulation tm flex duct insulation tm akoustiliner r tm ak flex tm. Preinsulated duct panel is an innovative technology for hvac ductwork system. Installation sheet ecofoil big8 duct insulation, r8. Design polymerics dp 2502 water based duct liner adhesive. You would, of course, be overlooking the majority of the true cost of duct system leakage. Other undetermined compounds could be released in small quantities. Absorbs fan and air turbulence noise and reduces popping noises within sheet metal ducts. The black faced surface of the duct liner shall face the airstream. Method statement for installation of hvac supply, return. Kimmco glasswool rockwool building insulation duct flow.

Kimmco duct insul plus kdip nominal density thermal and acoustic insulation external of hvac equipment and air distribution duct systems. By adopting advanced fabrication methods, the number of splitjoints can be reduced, which. Unlike fiber insulation alone, touch n seal spray polyurethane foam. Bonding fibrous duct wrap and duct liner insulation to galvanized duct work. Based on customer need to do away with flammable glue on construction sites, and meet leed, qsas and estidama requirements, kimmco introduces selfseal, an industryfirst glasswool insulation board for hvac duct insulation that is cleaner, faster and more costeffective than competing products. Applying up to 2 inches of touch n seal two component spray polyurethane foam insulation on attic floors prior to installing blownin or batt insulation adds up to r12 of additional thermal protection.

Ce marking kingspan koolduct panels are ce marked in conformance with bs en 14314 and a declaration of performance is available to download from uk. Design polymerics dp 2502 is a water based duct liner adhesive. By adopting advanced fabrication methods, the number of splitjoints can be reduced, which ensures less number of thermal breaks and uniform r value throughout the surface area. Kimmco duct insul plus kdip company profile kimmco kuwait insulating material manufacturing co. Aluglass facing ensures zero water vapour permeability, puncture resistance, and eliminates the need for external weather. Insulation solutions johannesburg house insulation. Maximum kvalue measured at 350c temperature and 60% relative humidity condition note 2. Imcolock international insulation distributors and. Other companies are charging thousands of dollars to set up accounts and give you access to their msds online database. Order johns manville duct insulation, 1 12 x 48 x 25ft, 670378 at.

Large pipes, pipe cluster, over heating traces where preformed insulation is not appropriate, round or oval duct work, square or rectangular ducts, where full. Duct insulation comes with code requirements for maximum efficiency the ductwork in your commercial facility, like the ductwork in your home, is the critical channel that carries heated and cooled air from your hvac system to your offices, warehouses and work areas. Tssc preinsulated duct panels are the exciting latest addition to our family of insulated panels. Project engineer responsibility roofing, insulation, and. Find details of companies offering duct insulation material at best price. Nomaco insulation polyolefin insulation is manufactured with one rough nonskin side and one smooth skin side. Kimmco duct insul plus with aluglass facing has added advantages. As 45081999 thermal resistance of insulation for ductwork used in building airconditioning. Exterior duct work must be pitched to allow rain water to run and seams with armatuff plus off surface, overlapping the side the insulation. Duct insul kdi duct insul plus kdip clean liner kcl duct system kads note i. Kimmco duct insul plus is manufactured from stable. Insulation product ef2280 r8 hvac duct wrap insulation tape ef151 or ef15112 hvac tape suggested products for this application. The products are applied to the external face of the ductwork and mechanically fixed into position with wire, elastic bands or tape.

Armaflex insulation products must be installed according to installation of armaflex insulations brochure. Company profile kimmco kuwait insulating material manufacturing co. The minimum thermal performance of insulation provided in. Please check out the similar products section for alternatives. Hvac duct systems operating at internal air velocities not exceeding rated duct liner limitations as listed below, and internal air temperatures between 29c and 250f 121c and air 20f velocities to 5,000 fpm 25. As a licensee of saintgobain isover, the world leader in fiberglass insulation, kimmco provides insulation solutions. Make sure that there is a spacer below the hanger between the insulation and the duct to prevent the insulation from touching the duct. Kimmco aluglass duct system is fabricated from the rigid board composed of resin bonded fine pure spun glass fibres faced with a foil glass cloth laminate aluglass water vapour barrier. For floating floor with a screed of cement or reinforced concrete in multi storey buildings such as dwellings, apartments etc kdip kimmco duct insul plus. For thermal and acoustic insulation external of hvac equipment and air.

As a licensee of saintgobain isover, the world leader in fiberglass insulation, kimmco provides insulation solutions for hvac, buildings including roofs, walls. Project engineer responsibility roofing, insulation. Quietr rotary duct liner residential insulation owens. Table f1 rvalues for common duct insulation materials 1 listed rvalues are for the insulation only as determined in accordance with astm c 518 at a mean temperature of 75f at the installed thickness and do not include air film resistance. Bonding kraft backed foil coverings to fiberglass and urethane flat stock or pipe insulation. To download product documentation, click on the icons above. Kimmco clean liner kcl kimmco clean liner is used to line air conditioning ducts, walls andor ceilings of acoustically sensitive areas to provide efficient sound insulation for any variety of structure, andor sensitive facilities as home theaters or studios, curtain walls. Kimmco kuwait insulating material manufacturing co. Without ductwork, even the best furnace, air conditioner, heat pump or boiler would be essentially useless, with no way to distribute the heating or cooling produced. A forced air duct system is designed to be a conduit for supply and return of conditioned air to and from occupied spaces of a building. Fire rated duct insulation for best results, display hidden notes to specifier. Internal insulation of sheet metal ducts sample specification 1. Climaver glass wool ductboards these are ducts made from high density glass wool board. Thermal insulation of heating, ventilation and air conditioning hvac ducting systems.

709 1285 800 784 898 1383 635 706 591 959 667 1460 615 1574 1309 297 1610 1178 239 146 1011 535 1325 652 1075 93 497 435 1332 1038 878 1335 218 1504 1109 1561 660 841 740 210 1195 699 1122 995 893 923